What was found
DURING C-CHECK, MAIN DECK COURIER AREA HAVE CORROSION EVIDENCE ON FLOOR PANEL SUPPORT/SEAT TRACK FROM APPROX FR 14 TO FR 19 RBL 36 (MARKED). REMOVED CORROSION FROM TRACK FR 14 TO FR 19 RBL 36. MATERIAL LOSS .025 FOUND OUT OF LIMITS AS PER A-300 SRM 53-10-00, FIG 612 AND SRM 51-40-11. REMOVED SEAT TRACK FROM FR 14 TO FR 19 RBL 36 AS PER A-300 SRM 51-30-30. MATERIAL USED 60-22457 PO 23236312. TREATED AND PRIMED AND POLYWHITE TRACK SECTION AS PER A-300 SRM 51-40-12. INSTALLED NEW SEAT TRACK SECTION SECTION FROM FR 14 TO FR 19 RBL 36 IAW A-300 SRM 51-30-30.