What was found
FUSELAGE SKIN DENTED AT FR26 BETWEEN STR29R & STR30R. REWORKED DENTED AREA AS REQUIRED IAW A300 SRM 51-41-10 AFTER REWORK FOUND DENT WITHIN LIMITS IAW A300 SRM 51-00-00 FIG 609. NOTE:08 DEPTH 1.5 LENGHT THICKNESS .063. HFEC INSPECTED AREA AT FR26 BETWEEN STR29R & STR30R IAW A300 NTM 51-30-00 PART 1 FOUND CRACK INDICATION. CUT OUT DAMAGED SKIN AREA DEBURR AND CLEAN EDGES IAW A300 SRM 53-10-10 FIG 705. HFEC INSPECTED CUTOUT AREA FOR CRACKS AS PER A300 NTM 51-00-00 PART 1, NO DISCREPANCIES FOUND. TREATED AND PRIMED AREA & DOUBLER PER A300 SRM 51-40-11. INSTALLED DOUBLER REPAIR AT FR26 BETWEEN STR29R & STR30R. MATL USED 2024T3 .071 SIZE 12 X 8 INCH PO 83113526 PER A300 SRM 53-10-10.