What was found
NR 3 FIRE PROTECTION SYSTEM GROUND DETECTOR CIRCUIT ANNUNCIATOR PULSES FAINTLY. ADJUSTED NR 3 FIRE PROTECTION SENSING ELEMENTS PER MM 26-11-01, OP'S CHECK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 3 FIRE PROTECTION SYSTEM GROUND DETECTOR CIRCUIT ANNUNCIATOR PULSES FAINTLY. ADJUSTED NR 3 FIRE PROTECTION SENSING ELEMENTS PER MM 26-11-01, OP'S CHECK NORMAL.