What was found
DURING A C-CHECK, LT FUSE HAS A DENT AFT BS 560 ABOVE STR 27L. DAMAGE FOUND TO BE OUT OF LIMITS IAW 727 SRM 53-30-1 FIG 1. CUT OUT DAMAGED AREA 57/8 X 21/4 AND FABBED FILLER FROM 2024 T3 .040 PO NR 9001030 DIM 57/8 X 1 AND DOUBLER FROM 2024 T3 .063 PO NR 9001061 DIM 281/4"X91/4" IAW 727 SRM 53-30-3 FIG3. PARTS TREATED, PRIMED AND INSTALLED IAW 727 SRM 51-10-2 AND 53-30-3 FIG 3.