What was found
DURING A C-CHECK, AFT CARGO FRAME BS 1010 HAS A DENT INTO THE RADIUS ABOVE STR 26L TO STR 24L. DAMAGE FOUND TO BE OUT OF LIMITS IAW 727 SRM 53-10-1 FIG 1. REMOVED EXISTING SPLICE, CUT OUT DAMAGED FRAME, FABBED NEW FROM 7075 T-6 .063 PO 900408 DIM 13.5 X 5.25 INCHES AND 1 MORE SPLICE FROM 7075-T6 .071 PO 900489 DIM 8 X 4.125 INCHES IAW 727 SRM 51-40-3 FIG 1 & 53-10-2 FIG 3. PARTS TREATED, PRIMED AND INSTALLED IAW 727 SRM 51-10-2 & 51-40-3 FIG 1.