What was found
DURING A C-CHECK, AFT CARGO FRAME BS 1030 HAS A DENT INTO THE RADIUS ABOVE STR 25L. DAMAGED AREA OUT OF LIMITS IAW 727 SRM 53-10-1 FIG 1. CUT OUT DAMAGED AREA DIM 1.75 X 1 INCH AND FABBED REPAIR ANGLE FROM 7075-T6 .071 PO 900489 DIM 11.75 X 4 INCHES IAW 727 SRM 51-40-2 FIG 3. DOUBLER (ANGLE) TREATED & PRIMED IAW 727 SRM 51-10-2 & INSTALLED IAW 727 SRM 51-40-3 FIG 1.