What was found
DURING A C-CHECK, LT FUSE HAS DENTS FWD BS 620 ABOVE STR 27L. DAMAGED AREA OUT OF LIMITS IAW B727 SRM53-30-1 FIG 1. CUT OUT DAMAGED AREA 14.125 X 4.75 INCH AND FABBED FILLER FROM 2024 T3 .050 PO 9001118 DIM 14.125 X 1.125 INCH AND DOUBLER FROM 2024 T3 .063 PO 900920 DIM 22.125 X 10.875 INCH IAW B727 SRM 53-30-3 FIG 3. PARTS TREATED AND PRIMED IAW B727 SRM 51-10-2. INSTALLED DOUBLER AND FILLER IAW B727 SRM 51-30-2.