What was found
DURING A C-CHECK, RT WING I/B FOREFLAP L/E HAS A DENT WS 335. DAMAGED FOUND TO BE OUT OF LIMIT IAW B727 SRM 57-50-1 FIG 3. CUT OUT DAMAGED AREA & FABBED FILLER FROM 2024 T3 .050 PO 900980 DIM 2.6875 INCH X 2.5 INCH & 2 EA DOUBLERS FROM 2024 T3 .063 PO 900790 DIM 5.75 X 3.25 INCH & 5.75 X 2.25 INCH IAW B727 SRM 57-50-4 FIG 2. PARTS TREATED & PRIMED IAW B727 SRM 51-10-2 PARTS INSTALLED IAW B727 SRM 57-50-4 FIG 2.