What was found
DURING A C-CHECK, THE FOLLOWING DISCREPANCIES WERE NOTED; RT WING LE SKIN DENT 4 INCHES OB OF IB LANDING LIGHT LE STA 120. CUT OUT 2EA DAMAGED AREAS, FABBED FILLERS FROM 2024-T3 .050 PO NR 900920 DIM 1INCH X 1INCH EA, 1EA DOUBLER FROM 2024-T3 .063 PO NR 900781 DIM 7.5 INCH X 6 INCH IAW SRM 57-30-4 FIG 5 REPAIR PARTS TREATED AND PRIMED IAW SRM 51-10-2 AND INSTALLED IAW SRM 57-30-4 FIG 5