What was found
DURING -C- CHECK, UPPER CABIN RIGHT SIDE BETWEEN STR 16R AND 17R FRAME IS DENTED AT BS 560. CUT OUT DAMAGE AREA SIZE .5 X 1 INCH ON UPPER CABIN RIGHT SIDE BETWEEN STR 16R AND 17R FRAME BS 560 IAW B727 SRM 51-10-1. FABRICATED, REPAIR ANGLE FROM 7075T6 .063 SIDE 4.5 X 6 INCH PO 900166 IAW B727 SRM 51-40-3 FIG 1. TREATED AND PRIMED PART AND AREA IAW B727 SRM 51-10-2. INSTALLED REPAIR ANGLE IAW B727 SRM 51-40-3 FIG 1.