What was found
DURING -C- CHECK, LEFT FUSELAGE HAS A DENT BS 1130 ABOVE STR 26L. DAMAGED FOUND TO BE OUT OF LIMITS IAW B-727-SRM 53-30-1 FIG 1. CUT OUT DAMAGED AREA SIZE 2 X 1.75 INCH AND FABRICATED DOUBLER FROM 2024-T3 .071 PO 900484 DIM 10 X 8.5 INCH STRUCTURAL FILLER FROM 2024-T3 .063 PO 900606 DIM 10 X 1.125 INCH IAW B-727-SRM 53-30-3 FIG 14. TREATED AND PRIMED PART AND AREA IAW B-727-SRM 51-10-2. INSTALLED DOUBLER REPAIR IAW B-727-SRM 53-30-3 FIG 14.