As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING -C- CHECK, FWD CARGO FLOOR SUPPORT IS BENT BS 600 RBL 3. CUT OUT DAMAGED AREA SIZE 1 X 4 INCH ON FWD CARGO FLOOR SUPPORT BS 600 RBL 3 IAW B727 SRM 51-10-1. FABRICATED FILLER FROM 2024T3 .063 SIZE 1 X 4 INCH PO 900606 AND ANGLE FROM BAC 1506-1080 SIZE 21.75 X 2 INCH PO 3425287 IAW B727 SRM 51-40-4 FIG 1. TREATED AND PRIMED PARTS AND AREA IAW B727 SRM 51-10-2. INSTALLED REPAIR PARTS IAW B727 SRM 51-40-4 FIG 1.