What was found
DURING -C- CHECK, DISCREPANCY AS FOLLOWS; UPPER CABIN RIGHT SIDE BETWEEN STR 16R AND 17R FRAME IS DENTED AT BS 540. CUT OUT DAMAGED AREA SIZE .75 X 1 INCH ON UPPER CABIN RIGHT SIDE BETWEEN STR 16R AND 17R FRAME AT BS 540 IAW B727 SRM 51-10-1, FABRICATED REPAIR ANGLE FROM 7075-T6 .063 SIZE 6 X 4.5 INCH PO 900166 IAW B727 SRM 51-40-3 FIG 1. TREATED AND PRIMED PART AND AREA IAW B727 SRM 51-10-2, INSTALLED REPAIR ANGLE IAW B727 SRM 51-40-3 FIG 1.