What was found
DURING C-CHECK, REPAIR AT BS 1130 BETWEEN STR 21R TO 24R DENTED AND ENDS ON STRINGER. REMOVED PREVIOUS REPAIR AND FOUND SKIN DENTED OUT OF LIMITS IAW B-727 SRM 53-30-1 FIG 1. REMOVED RT AFT SIDEWALL IN AFT PIT FOR ACCESS IAW B-727 MM 25-52-02. CUT OUT DAMAGED AREA DIM 1.625 INCH X 1.625 INCH AND FABBED FILLER FROM 2024 T3 .063 PO 900355 DIM .5 INCH X .5 INCH AND DOUBLER FROM 2024 T3 .071 PO 900408 DIM 11.5 INCH X 11 INCH IAW B-727 SRM 53-30-3 FIG 3. PARTS TREATED AND PRIMED IAW B-727 SRM 51-10-2 AND INSTALLED IAW B-727 SRM 53-30-3 FIG 3. REINSTALLED LINER IAW B-727 MM 25-52-02.