What was found
DURING C-CHECK, LT INBOARD FOREFLAP UPPER INBOARD SURFACE PREVIOUS REPAIR DELAMINATED. REMOVED DELAMINATED PREVIOUS REPAIR. FABRICATED FILLER APPROX 13 INCH X 13 INCH AND DOUBLER APPROX 13 INCH X 5 INCH FROM 2024 T3 .016 PO 900291. CLEANED, PREPPED, APPLIED ADHESIVE PRIMER AND ADHESIVE TO ALL REPAIR PARTS. BONDED, CLEANED, TREATED, PRIMED AND SEALED REPAIR IAW B-727 SRM 57-50-1 FIG 3, 51-40-6 FIG 2, 57-50-2 FIG 3, 51-40-20 FIG 30. BONDED RUBSTRIP IAW B-727 MM 51-51-11.