What was found
DURING A C-CHECK, THE FOLLOWING DISCREPANCIES WERE NOTED; RT WING OUTBD AFT FLAP SHOW SPOTS 2 EA OF DISBOND OF WBL 279 & WBL 395. T/E UPPER SIDE. CUT OUT DELAMINATED AREAS AT RT OUTBD AFT FLAP APPROX 1.25 X 10 INCH AND 1.5 X 1.5 INCH. APPLIED ADHESIVE PRIMER AND FABRICATED FILLERS 1.5 X 1.5 INCH AND 1.25 X 10 INCH AND DOUBLERS 3 X 3 INCH AND 2.5 X 12 INCH FROM .016 INCH 2024 T3 PO 9912030. BONDED REPAIR PARTS, CURED, CLEANED, PRIMED AND SEALED IAW B-727 SRM 57-50-2 FIG 4 AND 51-40-20 FIG 30.