What was found
DURING A C-CHECK, THE FOLLOWING DISCREPANCIES WERE NOTED; LT WHEEL WELL BS 950 AFT DOOR STOP BRACKET IS LOOSE FROM WEB ATTACH ANGLES. REMOVED HYD LINES 4EA FOR ACCESS FOR S/M REPAIR IAW B-727-M/M 20-10-5. REMOVED BRACKETS 2EA ON LT WHEEL WELL BS 950 AFT DOOR STOP FROM WEB AND ACCESS PANEL IAW B-727-SRM 51-30-2. FABRICATED 2EA BRACKETS DIM 19.5 X 5 INCH PO 900576 MAT. 2024-T3 .050 IAW B-727-SRM 51-40-3 FIG 1. TREATED AND PRIMED PARTS AND AREA IAW B-727-SRM 51-10-2. INSTALLED 2EA BRACKETS IAW B-727-SRM 51-30-2. REINSTALLED 4EA HYD LINES AND ACCESS PANEL IAW B-727 M/M 20-10-5.