What was found
DURING C-CHECK, NR 2 SLAT AT I/B TRACK ATTACH WBL 592 HAS OTBD FRAME WITH CRACK IN FWD LOWER RADIUS. STOP DRILLED CRACK NR 2 SLAT I/B TRACK WBL 592 IAW B727 SRM 51-10-1. FABRICATED DOUBLER P/N CRESS AISI 321.032 PO 900878, 5 X 3 INCH IAW B727 SRM 57-50-3, NDT ACCOMPLISHED HFEC INSPECTION 51-00-00 FIG 4 END OF CRACK FOUND. INSTALLED DOUBLER REPAIR IAW B727 SRM 51-30-2. RE-INSTALLED NR 2 SLAT I/B TRACK IAW B727 MM 27-81-11, OPS CHECK OK IAW B727 MM CH 27-81-11.