What was found
DURING C-CHECK, LEFT I/B MID FLAP UPPER SURF WBL 93 NEAR L/E HAS SKIN GOUGED. GOUGE IN SKIN FOUND TO BE OUT OF LIMITS NDT VERIFY NO FURTHER DAMAGE IAW B727 SRM 57-50-1. REMOVED DAMAGED AREA OF SKIN 1 X 1 INCH IAW B727 SRM 57-50-4. FABRICATED DOUBLER FROM 2024-T3, 4.8 X 4.8 INCH AND FILLER FROM 2024T3.063, .9 X .9 INCH IAW B727 SRM 57-50-4. ALODINED & PRIMED REPAIR PARTS IAW B727 SRM 51-10-2. INSTALLED REPAIR DOUBLER & FILLER IAW B727 SRM 57-50-4 FIG 10.