What was found
NR. 1358: RT WING CENTER L/E UPPER FORMER CRACKED 0.500, STA. XFS 379.000. REMOVED FASTENERS IAW SRM51-1-20D PG. 21, SRM 51-1-21 PG.1. FABRICATED ANGLE DOUBLER (2024-T3 0.032)IAW SRM 57-2-0 PG. 9-10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLER WITH NEW FASTENERS IAW SRM 51-1-20D PG.9, SRM 51-1-21 PG.1, SRM 57-2-0 PG. 9-10.