What was found
RT VERTICAL STABILIZER LWR ANGLE CRACKED 1.500, ZR 47.000 (RT) REAR SPAR PLANE. PERFORMED MAJOR REPAIR IAW SRM 53-2-5 FIG 16A SHEET 1-2 PAGES 44 ABCD. REMOVED FASTENERS IAW SRM 51-1-21 PG.1. TRIMMED OUT DAMAGED AREA IAW SRM 53-2-5 FIG 16A SHEET 1-2. FABRICATED SHIM (AL2024-T3 0.125) FILLER (AL7075-T6 0.160) ANGLE (STEEL 17.7PH 0.079) IAW SRM 53-2-5 PAGES 44 ABCD FIG 16A (SHEET 1-2). PERFORMED HEAT TREATMENT TO STEEL ANGLE IAW SRM 51-1-6. PERFORMED NDT INSPECTION IAW NDT SPM PART 08-00-02/07. CLEANED, TREATED AND PRIMED AREA, SHIM AND FILLER IAW SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG.9. INSTALLED SHIM, FILLER AND ANGLE IAW SRM 53-2-5 FIG 16A (SHEET 1-2) PAGE 44 ABCD.