What was found
LEFT VERTICAL STABILIZER LWR ATTACH ANGLE CRACKED 4.000, ZR 47.000 (FRONT SPAR PLANE) (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW DC8 SRM 53-2-5 FIG 16A SHEET 1-2 PG 44A,B,C,D. REMOVED FASTENERS IAW DC8 SRM 51-1-21 PG 1. CUT OUT DAMAGED SECTION IAW DC8 SRM 53-2-5 FIG 16A SHEET 1-2. FABRICATED SHIM (AL7075T6 0.125), FILLER (AL7075-T6 0.160) AND ANGLE (STEEL 17.7 PH 0.079) IAW DC8 SRM 53-2-5 PG 44A, B, C, D FIG 16A SHEET 1-2. HEAT TREATED STEEL ANGLE IAW DC8 SRM 51-1-6. PERFORMED NDT INSP IAW NDT SPM PART 08-00-02/07. CLEANED, TREATED AND PRIMED AREA, SHIM AND FILLER IAW DC8 SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW DC8 SRM 51-1-11 PG 9. INSTALLED SHIM, FILLER AND ANGLE.