What was found
LT WING IB. VANE SLOR HOLES ELONGATED STA XS 247.000. PERFORMED MAJOR REPAIR IAW ED EDV43-9, DWG V43-R09. REMOVED FASTENERS IAW SRM 51-1-21 PG.1, SRM 51-3-0 PG.1, SRM 51-1-20D PG.21. TRIMMED OUT DAMAGED SECTION IAW ED ECV43-9, DWG V43-R09. PERFORMED NDT INSP. IAW DC8 NDT SPM PART 6-10-01.001. FABRICATED FILLER (7075-T6AL 0.063) AND DOUBLER (7075-T6AL 0.071) IAW ED EDV43-9, DWG V43-R09. CLEANED, TREATED AND PRIMED AREA AND INNER FACE OF FILLER AND DOUBLER IAW SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG.9. INSTALLED FILLER, DOUBLER AND NEW FASTENERS IAW ED EDV43-9, DWG V43-R09, SRM 51-1-21 PG.1, SRM 51-1-20D PG.9, SRM 51-3-0 PG.1.