What was found
MAIN CARGO COMPT PRESSURE PANEL ATTACH ANGLE CORRODED AT STA 857.125 RBL 29 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW DC8 SRM 51-2-1 PG 8-14. REMOVED CORROSION FROM PRESSURE PANEL ATTACH ANGLE AT STA 857.125 RBL 29 IAW DC8 SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW DC8 SRM 53-2-0 PG 2M. CUT OUT DAMAGED SECTION IAW DC8 SRM 51-2-1 PG 8. FABRICATED FILLER (7075-T6 0.125) AND REPAIR ANGLE (7075-T651) IAW DC8 SRM 51-2-1 PG 8-14. CLEANED, TREATED AND PRIMED IAW DC8 SRM 51-1-8B. INSTALLED FILLER AND REPAIR ANGLE IAW DC8 SRM 51-2-1 PG 8-14, DC8 SRM 51-1-21 PG 1, DC8 SRM 51-3-0 PG 1, DC8 SRM 51-1-20D PG 9.