What was found
MAIN CARGO COMPT FITTING CRACKED 1.000, STA. 702.000, RBL 25. REMOVED CRACKED FITTING AT STA 702.000 RBL 25 IAW DC8 SRM 53-1-0 PG 1, SRM 51-1-20D PG 21. FABRICATED NEW FITTING IAW EA5320-029, DWG 4751820. PERFORMED NDT INSPECTION IAW NDT SPM PART 08-00-02/07. CLEANED, TREATED AND PRIMED AREA AND NEW FITTING IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D PG 9.