What was found
ITEM REF. NR. 0848: REPAIR OF DENT AND BROKEN CRACK TO RT WING IB AILERON UPPER PLATING AT XW 563.000 PERFORMED MAJOR REPAIR IAW ED-EDW 27-1, DWG W27-R01 REV IR. REMOVED EXISTING FASTENERS ON AREA IAW SRM 51-1-21 PG. 1, SRM 51-1-20D PG. 21. TRIMMED OUT DAMAGED AREA IAW DWG W27-R01, EDW 27-1. FABRICATED FILLER AND DOUBLER (AL 2024-T3 0.050) IAW DWG W27-R01, ED EDW 27-1. CLEANED, TREATED AND PRIMED AREA AND FILLER AND DOUBLER INTERNAL PART IAW SRM 51-1-8B. APPLIED PRC SEALANT ON FAYING SURFACES IAW SRM 51-1-11 PG.9. INSTALLED FILLER AND DOUBLER WITH NEW FASTENERS IAW DWG W27-R01, ED EDW 27-1, SRM 51-1-21 PG.1. FOR IB AILERON REBALANCE SEE NR 0896. FOR OPS CHECK SEE NR 0794.