What was found
RIGHT OUTER WING OUTBOARD L/E FORMER CRACKED 0.250 AT STA XFS 791.250. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. PERFORMED STOP HOLE ON CRACK END AND FABRICATED ANGLE DOUBLER (2024T3 AL 0.032) IAW SRM 57-2-0 PG 9,10. CLEANED, TREATED AND PRIMED ANGLE DOUBLER IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLER IAW SRM 57-2-0 PG 9, 10, SRM 51-1-21 PG 1, SRM 51-1-20D PG 9.