What was found
FUSELAGE NOSE SECTION EXTERIOR SKIN CRACKED 0.250 AT STA 53.000 L-30L (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 13. REMOVED EXISTING REPAIR IAW SRM 51-1-20D PG 21. TRIMMED OUT CRACKED AREA IAW SRM 53-2-0 FIG 13. FABRICATED FILLER (2024T3AL 0.050) AND DOUBLER (2024T3AL 0.071) IAW SRM 53-2-0 FIG 13. CLEANED, TREATED AND PRIMED AREA, FILLER AND DOUBLER IAW SRM 51-1-8B. APPLIED PRC SEALANT ON FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED FILLER AND DOUBLER IAW SRM 53-2-0 FIG 13, SRM 51-1-20D PG 9.