What was found
FWD ACCY COMPT BEAM JOINT ANGLE WITH INTERCOSTAL CRACKED 2.000 STA 70.000 LBL 47. REMOVED CRACKED ANGLE IAW SRM 51-3-0 PG 1. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW ANGLE IAW SRM 51-3-1 PG 1, 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD ACCY COMPT BEAM JOINT ANGLE WITH INTERCOSTAL CRACKED 2.000 STA 70.000 LBL 47. REMOVED CRACKED ANGLE IAW SRM 51-3-0 PG 1. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW ANGLE IAW SRM 51-3-1 PG 1, 2.