What was found
EXTERNAL FUSELAGE - EXTERNAL SKIN CRACKED 0.500 AT STA 194.000 L-30L (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-1 FIG 7 SHEET 1, 3, 5. TRIMMED OUT DAMAGED AREA IAW SRM 53-2-1 FIG 7 SHEET 1, 3, 5. FABRICATED FILLER (AL7075-T6 0.071) FINGER DOUBLER (AL7075T6 0.050) DOUBLER (AL7075T6 0.080) IAW SRM 53-2-1 FIG 7 SHEET 1, 3, 5 SRM 53-4-1 PG 7 FIG 4. CLEANED TREATED AND PRIMED AREA AND REPAIRED PARTS IAW SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED REPAIRED PARTS WITH NEW FASTENERS IAW SRM 53-2-1 FIG 7 SHEET 1, 3, 5 SRM 51-1-21 PG 1, SRM 51-1-20D PG 9.