What was found
MAIN CARGO COMPT FRAME MISDRILLED HOLE AT STA 1200.000, L-12R TO L-13R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW DWG W90-R19, REV:IR DATED 11-22-04 FAA FORM 8110-3 DATED 11-29-04. REMOVED EXISTING DAMAGED FRAME SPLICE PLATE AND FASTENERS IAW DWG W90-R19, SRM 51-1-21 PG 1, SRM 51-1-20D. FABRICATED EXTERNAL REPAIR DOUBLER STRAP (AL7075-T6 0.090) AND FRAME SPLICE PLATE (7075T6 0.063) IAW DWG W90-R19. CLEANED, TREATED AND PRIMED MISDRILLED HOLES AREA IAW SRM 51-1-8B. PLUGGED MISDRILLED HOLES WITH RIVETS (NAS1097AD5) IAW SRM 51-1-21 PG 1, DWG W90-R19. INSTALLED EXTERNAL REPAIR DOUBLER STRAP AND FRAME SPLICE PLATE WITH NEW FASTENERS IAW DWG W90-R19, SRM 51-1-21 PG 1.