What was found
LEFT WING ROOT FIXED LEADING EDGE HAS LOWER ANGLE SUPPORT CRACKED L/E STA 130. REMOVED FASTENERS FOR ACCESS AT LEFT WING ROOT FIXED EDGE L/E STA 130 STOP DRILLED CRACK .250 TERMINATED AT END OF CRACKED IAW B727 SRM 51-10-1 NDT HFEC INSP PER B727 NDT MAN PT6 51-00-00 FIG 23. CRACK ENDS IN STOP DRILL HOLE. FABRICATED ANGLE REPAIR MAT USED 2024 T3 .063 PO 9002118 DIM 9.5 X 2 INCHES IAW B727 SRM 51-40-3 FIG 1 AND 57-20-2. ALODINED AND PRIMED AREA AND PART IAW B727 SRM 51-10-2. INSTALLED ANGLE REPAIR IAW B727 SRM 51-40-3 FIG 1 AND 57-20-2 FIG 1.