What was found
DENT RT FUSELAGE SKIN 4 INCHES AFT OF STA 1342.4 STRINGER 22R. REMOVED FASTENERS FOR ACCESS IAW B727 SRM 51-30-2 CUTOUT DAMAGED AREA ON RT FUSELAGE STA 1342 STR 22R AND 23R SIZE 3 X .750 INCHES AND 1 X .500 INCHES IAW B727 SRM 54-30-3 FIG 7. FABRICATED DOUBLER REPAIR WITH 2024T3 .063 SIZE 16.750 X 10 INCHES PO 9002039 IAW B727 SRM 54-30-3 FIG 7 AND 54-30-2. TREATED AND PRIMED PART AND AREA IAW B727 SRM 51-10-2 AND INSTALLED DOUBLER REPAIR IAW B727 SRM 54-30-3 AND 51-30-2.