What was found
VERT STAB ABOVE RT FIN STA 133 LOWER RUDDER SURF IS DENTED NEAR T/E. EVAULATED DENTED AREA AT VERT STAB ABOVE RT FIN STA 133 LOWER RUDDER SURF. TRIM OUT DAMAGED SKIN SIZE 1/2" BY 3/4" IAW B727 SRM 55-30-3 AND 51-10-1. FABRICATED DOUBLER REPAIR SIZE 2" BY 2.5" MAT USED 2024-T3 .032 PO 9002034 IAW B727 SRM 55-20-3 FIG 1. ALODINED AND PRIMED IAW B727 SRM 51-10-2. INSTALLED DOUBLER REPAIR AT VERT STAB BELOW FIN STA 133 LOWER RUDDER SURFACE IAW B727 SRM 51-30-2 AND 55-20-3 FIG 1.