What was found
FRAME BENT AT FUSELAGE STA 700 STR 24R. CUT OUT DAMAGED AREA DIM 2.250 IAW B727 SRM 51-10-1 FIG 1. FABBED ANGLE REPAIR FROM 7075-T6 .063 PO NR 900489 DIM 11 X 3 INCHES. FABBED SHIM FROM 7075-T6 .100 PO NR 9911586 DIM 11 X 1 INCHES. FABBED FILLER FROM 7075-T6 .050 PO 9001417 DIM 2.5 X 1 INCHES, IAW B727 SRM 53-10-2 AN 51-40-3 FIG 3. ALODINED AN PRIMED PART REPAIR IAW B727 SRM 51-10-2 AND INSTALLED FRAME REPAIR IAW B727 SRM 51-40-3 FIG 3 AND 51-30-2.