What was found
STRINGER AND FRAME CORRODED AT FUSE STA 720,STR 26R. REMOVED FASTENERS AN STRINGER 19.50 INCH AT STA 720 STR 26R IAW B727 SRM 51-30-2 AN 53-10-3 FIG 1. FABRICATED STRINGER REPLACEMENT PN BAC 1498-144, PO NR 335792 SIZE 19.50 INCH AN 2 SPLICES PN BAC 1498-132 SIZE 14 IAW B727 SRM 53-10-3 FIG 1. ALODINED AN PRIMED REPAIR PARTS AN AREAS IAW B727 SRM 51-10-2. REMOVED CORROSION LIGHT CORROSION FRAME AT STA 720 STR 26R IAW B727 51-10-6 MAT. LOSE .002 FOUND TO BE WITHIN LIMITS IAW B727 SRM 53-10-1 FIG 1 AND INSTALLED STRINGER AN 2 SPLICES IAW B727 SRM 53-10-3 FIG 1, 51-30-2.