As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DENT ON RT FUSELAGE STA 1346 AT STR 13 MARED NR 51. CUT OUT DAMAGE AREA SIZE 2.50 X .250 IAW B 727 SRM 54-30-1 FIG 1. FABRICATED DOUBLER USING 2024T3 .050 PO NR 9002219 DIM 11.50 BY 10 AND FILLER USING 2024T3 .040 PO NR 9001030 DIM 2.50 X .250 IAW B 727 SRM 54-30-2 FIG 4. ALODINED AN PRIMED PARTS IAW B727 SRM 51-10-2. INSTALLED DOUBLER IAW B727 SRM 54-30-3 FIG 7.