What was found
FRAME BENT AT FUSE STA 680 STR 24R. FOUND DENT TO BE OUT OF LIMITS ON STA 680 STR 24R IAW B727 SRM 53-10-1 FIG 1 SIZE 2 INCHES BY 2 1/2 INCHES CUTOUT FABRICATED ANGLE REPAIR FROM 7075T6 .071 SIZE 12 INCHES BY 3 INCHES PO NR 900573 IAW B727 SRM 51-40-3 FIG 1. TREATED AND PRIMED PART AND AREA IAW B727 SRM 51-10-2. INSTALLED REPAIR ANGLE IAW B727 SRM 51-40-3.