As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BENT FRAME AT STA 500 STR 25R. CUT OUT DAMAGED AREA DIM 3 INCHES BY 1/8 INCHES ON FRAME STA 500 STR 25R IAW B727 SRM 51-10-1. FABRICATED REPAIR ANGLE FROM 7075T6 .063 SIZE 13 3/8 INCHES BY 3 1/8 INCHES PO NR 9001660 IAW B727 SRM 51-40-3 FIG1. TREATED AND PRIMED PART AND AREA IAW B727 SRM 51-10-2. INSTALLED REPAIR ANGLE IAW B727 SRM 51-40-3 FIG 1.