As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND REPLACE TEE ANGLE AT BS RBL 60-LBL 60 FOR 9-G BARRIER INSTALLATION. REMOVED TEE ANGLE BS 344 FROM LBL 60 -LBL 60. LOCATED AND DRILLED HOLES IN REPLACEMENT PART IAW B727 SRM 51-30-2 FIG 1. TREATED AND PRIMED PART IAW B727 SRM 51-10-2. INSTALLED REPLACEMENT PART NR BAC 1505-29222 PO NR 9002149 (12FT) FROM LBL 60 -LBL 60 IAW B727 SRM 51-30-2 AND STC ST0088LA.