What was found
DENT ON RT FUSELAGE STA 1140 BELOW STR 25R. EVALUATED DENT AT BS 1140 STR 25R IS BEYOND ALLOWABLE LIMITS IAW B727 SRM 53-30-1 FIG 1, CUT OUT DAMAGED SECTION, DIM 4 X 2 INCH IAW B727 SRM 53-30-3 FIG 1. FABRICATED REPAIR DOUBLER 2024-T3 .071 DIM 13 X 8 INCH IAW B727 SRM 53-30-2 FIG 4 AND 53-30-3 FIG 1, TREATED AND PRIMED, PART AND AREA IAW B727 SRM 51-10-2, INSTALLED REPAIR DOUBLER IAW B727 SRM 53-30-3 FIG 1.