What was found
STRUCTURE SUPPORT FRAMES AT JACK POINT FROM BS 350 TO 360 IS CORRODED. REMOVED FWD & AFT FRAME AT BS 351 STR 22 RT IAW B727 SRM 51-30-2. FWD & AFT FRAME FOUND TO BE CORRODED BEYOND ALLOWABLE LIMITS. FAB FWD FRAME FROM 7075T6 .071 29 X 4.5 INCH PO9002118 & AFT FRAME FROM 7075T6 .063 40 X 13 INCH PO 50962574 IAW B727 SRM 53-10-1 FIG 1 & 53-10-2. TREATED & PRIMED 2 EA FRAMES IAW B727 SRM 51-10-2. INSTALLED FWD & AFT FRAMES AT BS 351 IAW B727 SRM 51-30-2.