What was found
FLOORBEAM AT BS 1110, BL-0, LWR CHORD IS EXFOLIATED. REMOVED WEB FOR ACCESS FROM STA 1110 BL 0 TO STA 1130 BL 0 IAW B727 SRM 51-30-2. CUT OUT DAMAGED AREA FLOORBEAM LOWER CHORD STA 1110 BL 0 SIZE 4.5 X 2 INCH IAW B727 SRM 53-10-8. FABRICATED REPAIR ANGLES FILLER AND STRAP MAT USED ANGLES 7075-T6 .071 SIZE 16.5 X 2.25 INCH PO 5096275 FILLER 7075-T6 .0125 SIZE 4.5 X 2 INCH PO 9912445 STRAP 7075-T6 .100 PO 9911586 SIZE 18.5 X 2 INCH IAW B727 SRM 53-10-8. TREATED AND PRIMED IAW B727 SRM 51-10-2. INSTALLED REPAIR AT FLOORBEAM CHORD STA 1110 BL 0 IAW B727 SRM 53-102. INSTALLED WEB WHICH WAS REMOVED TO GET ACCESS TO THE DAMAGED AREA FROM STA 1110 TO 1130 BL 0 IAW B727 SRM 51-30-2.