As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DENT AT RIGHT FUSELAGE STA 1330 ABOVE STR 19R. CUT OUT DAMAGE AREA SIZE 1.75 X 2.75 INCH ON RIGHT FUSELAGE STA 1330 ABOVE STR 19R IAW B727 SRM 53-30-3 FIG 1. FAB'D DOUBLER FROM 2024-T3 0.63 SIZE 7.5 X 10.75 INCH PO 9001978. TREATED & PRIMED PART AND AREA IAW B727 SRM 51-10-2. INSTALLED REPAIR DOUBLER IAW B727 SRM 53-30-3 FIG 1 & 51-30-2.