As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NUT PLATES IMPROPERLY INSTALLED ON FLOOR SUPPORT BETWEEN BS 1070 - BS 1130 STR. 30 (ABOVE) REMOVED DAMAGED FLOOR SUPPORT BETWEEN BS 1070 - 1130. CUT AND FABRICATED NEW SUPPORT 13INCHES FROM BAC1490-2583 AND SPLICES 12 INCHES X 1INCH X 1INCH FROM AND10133-0702 AND 89.5 INCHES X 1INCH X .8750 INCH FROM BAC1509-100146. DRILLED, TREATED AND PRIMED AND INSTALLED IAW SRM 53-10-5 FIG. 4 AND SRM 51-30-2.