What was found
E&E DOORS AFT CROSS MEMBER IN ENTRYWAY CRACKED INSIDE LIP 4.5 INCHES OFF CENTER RT SIDE (MARKED). REMOVED FASTENERS AND FRAME IAW B727 SRM 51-30-2. FABBED NEW FRAME 7075 T6 PO9001873 1050 24"X6" IAW B727 SRM 53-10-2 FIG 1. TREATED AND PRIMED PART IAW B727 SRM 51-10-2. INSTALLED NEW FRAME AFT OF E&E DOOR IAW B727 SRM 51-30-2.