What was found
BENT FRAME ABOVE STR 17R AT BS 580. CUT OUT DAMAGED AREA OF FRAME 1.8 BY 1.7 FAB REPAIR CHANNEL 10 BY 4 .050 7075 T6 PO NR 9001777 IAW B727 SRM 53-10-4 FIG 1. TREATED AND PRIMED ALL BARE SURFACES IAW B727 SRM 51-10-2. INSTALLED REPAIR CHANNEL IAW B727 SRM 53-10-4 FIG 1.