What was found
FOUND DENT ON FRAME AT BS 500 ABOVE STR 24R. CUT OUT DAMAGED AREA 4 1/8" BY 1 1/8" FROM FRAME ON BS 500 ABOVE STR 24R IAW B727 SRM 51-40-3 FIG 1. FAB REPAIR DOUBLER 12" BY 2 1/8" OF 7075 T6 .063 PO 9002351 IAW B727 SRM 51-10-2 FIG 3 AND 51-40-3 FIG 1. TREATED AND PRIMED IAW B727 SRM 51-10-2. INSTALLED REPAIR PART IAW B727 SRM 51-30-2 AND 51-40-3 FIG 1.