As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME AT STA 970 ABOVE STR 26 LT IS DENTED M/R. CUT OUT DAMAGED AREA 7/8" BY 2 3/4" AND FABBED REPAIR ANGLE FROM 7075 T6 .063 PO 9002351 DIM 4" BY 10 7/8" IAW B727 SRM 51-40-3 FIG 1 AND 53-10-2. TREATED AND PRIMED IAW B727 SRM 51-10-20. INSTALLED REPAIR ANGLE IAW B727 SRM 51-40-3 FIG 1.