As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD LWR CARGO DOOR DENTD AT BS 615 BETWEEN STRS 23R AND 24R MARKED. CUT OUT DAMAGED AREA DIM 2 INCHES BY 1 INCH FABBED DOUBLER 2024T3 .063 PO5070593 DIM 9 3/4 INCHES BY 8 INCHES IAW B727 SRM 52-00-30 FIG 3. TREATED AND PRIMED REPAIR EREA AND PART IAW B727 SRM 51-10-2. INSTALLED DOUBLER IAW B727 SRM 52-00-3 FIG 3.